Every module is a service. Every module speaks the same events.

Digital Twin is a set of independently scalable engines on a streaming event backbone, a CIM-aligned twin model, and a 28-screen operations console. This page lists what ships today, how it is wired, and what is on the roadmap, with honest statuses.

Modules

Operate, plan and model from one console.

Dynamic line ratings & forecast

IEEE 738-2012 steady-state heat balance on live weather cells and measured load. Real-time DLR, 0–240 h forecast with 1-σ uncertainty bands, study mode and FERC 881-style evidence export.

/ratings · /forecastIEEE 738-2012CIGRE TB 601 (R2)

Situational awareness (God's Eye)

One geospatial operating picture across every site: flows, ratings, alarms, health. Seven display modes, tours, follow-mode, whiteboard markup, time travel and natural-language commands.

/gods-eye7 display modesguided tours

Fleet & asset health

Health index and remaining useful life per asset from physics-informed models: transformer hot-spot ageing, wind power-curve deviation, PV performance ratio, ISO 10816 vibration zones, breaker contact wear.

/fleetIEEE C57.91IEC 61400-12IEC 61724ISO 10816-3IEC 62271

3D site twin

Substations, plants, wind and solar parks, refineries and mines in 3D with live sensor overlays, thermal views, inspection mode and what-if physics per equipment.

/twinlive sensor overlayswhat-if physics

Insights, recommendations & ROI ledger

Streaming anomaly detection plus threshold alarms with hysteresis on 60+ tags. Every recommendation carries expected MW, expected USD and confidence; status tracks open → accepted → realised.

/insights · /actionsexpected vs realisedconfidence-scored

Incidents, work orders & dispatch

Alarm-to-crew workflow with SLA timers, dual-control approvals (second approver enforced server-side), fleet dispatch and a SHA-256 hash-chained audit ledger.

/incidents · /work-orders · /dispatchdual controlSLA timers

Enterprise operations: MES, stock & supply chain

Production orders and OEE per work center, spare-parts stock with reorder points, purchase orders with supplier OTIF and shipment risk, and maintenance plans tied to asset health — all on the same twin and event backbone.

/mes · /warehouse · /supply-chain · /maintenanceOEEOTIFMTBF / MTTR

Hosting capacity & developer portal

Feeder-level hosting capacity with smart-inverter and flexible-interconnect options, IEEE 1547 screening, 8760-hour profiles and a persisted interconnection queue with stage SLAs.

/hosting-capacity · /portalIEEE 1547DC power flow

Scenario studio & playback

DC power-flow engine with island detection for outage, weather and load scenarios; full historical playback of the twin state.

/scenarios · /playbackDC power flowisland detection

Data quality scoring

Per-tag 0–100 quality score from gap, flatline, spike and drift detectors, so operators know when a number cannot be trusted before they act on it.

every tag · every screengap · flatline · spike · drift

Lansub AI — self-hosted operations agent

A small language model that runs entirely inside your perimeter — no telemetry leaves the site. It reads every module (twin, alarms, health, MES, stock, supply chain, maintenance), answers with citations, drafts governed actions and learns from outcomes and operator feedback.

Lansub AI dock · every screen62 toolsself-hosted SLMepisodic memory

Compliance & administration

Tenants, users and roles, API keys, integrations, retention tiers, ontology versions, feature flags and the audit ledger, with identity provided by the built-in identity service.

/compliance · /adminRBAC · 6 roleshash-chained audit

Digital Twin · 3D Site Twin
Digital Twin · 3D Site TwinDigital Twin · 3D Site Twin
3D Site Twin — Khavda PS-4 hybrid park with live sensor overlays.
Digital Twin · Scenario Studio
Digital Twin · Scenario StudioDigital Twin · Scenario Studio
Scenario Studio — DC power flow with island detection for outage and load cases.
Digital Twin · Hosting Capacity
Digital Twin · Hosting CapacityDigital Twin · Hosting Capacity
Hosting Capacity — feeder headroom, IEEE 1547 screening and the interconnection queue.

Architecture

Ingest once, compute everywhere.

A single telemetry contract feeds every engine; each consumes what it needs and publishes back. The console subscribes live, so an alarm or rating change reaches the operator in well under a second.

SCADA / historianEdge collectorsWeather cellsGIS / EAMEvent backbonevalidated telemetry · weatherratings · alarms · healthrecommendations · quality scoresRatings engineIEEE 738Health engineC57.91 / 61400 / 61724Insightsanomalies & recoData qualityper-tag scorePower flowstudiesConsolelive pushHistorytime series

Platform layers

ConnectRead-only acquisition from SCADA, historians, IoT devices, weather and files; every reading validated against a versioned contractMQTT · OPC UA · Modbus · LoRaWAN
Twin modelCIM/CGMES-aligned asset registry with geometry, versioned attributes and full history50+ equipment classes
Physics enginesLine ratings, equipment health, remaining useful life and power-flow studies, recomputed every secondIEEE · IEC · ISO models
Data qualityGap, flatline, spike and drift detection scores every tag 0–100 before anyone acts on itper-tag scoring
InsightsThreshold and streaming-anomaly detection; recommendations carry expected MW, USD and confidenceoutcome-tracked
Operations workflowWork orders, incidents, dispatch, dual-control approvals and the interconnection queue with SLA timershash-chained audit
Enterprise operationsProduction orders & OEE, spare-parts stock, purchase orders and maintenance plans on the same twinMES · stock · supply · maintenance
Lansub AISelf-hosted agent and autopilot with episodic memory and feedback learning62 tools
Identity & auditTenants, six platform roles, SSO federation and an immutable audit ledgerRBAC · dual control
Live deliverySub-second push of every alarm, rating and health change to every open consolereal-time

Data streams

streamcarriesgranularity
Telemetryvalidated readings with quality codes1 s cadence
Weathergridded observations and forecastsper weather cell
Ratingsreal-time + 0–240 h forecast with uncertaintyper line span
Healthhealth index, remaining useful life, riskper asset
Alarms & anomaliesthreshold + streaming detectionsseverity-graded
Recommendationsexpected MW / USD / confidence → realisedoutcome-tracked
Governed actionsapprovals, write-back commands and resultsdual control
Enterprise opsproduction, stock, supply and maintenance eventscross-module

All contracts are versioned; customer integrations consume them through the platform API.

Integrations

Works with the systems you already run.

Connectors are listed with their real state. 'Planned' means the interface exists in the admin registry and on the roadmap; it does not mean a certified driver ships today.

SystemVendors / productsProtocolsStatus
Historian / SCADAAVEVA (OSIsoft) PI, GE ProficyPI Web API, OPC UA, IEC 61850 MMS/GOOSE, DNP3, Modbus TCP, MQTT / Sparkplug Bconnector roadmap R0–R2
EMS (advisory feed)GE Vernova e-terraadvisory export; write-back feature-flagged (R4)planned
EAM / work managementIBM Maximo, SAP PMREST, bidirectional work ordersplanned
GIS / network modelEsri ArcGIS Utility Network, GE SmallworldFeatureService, CIM/CGMES XMLplanned
Weather (NWP)gridded forecast providersweather.grid topic per celllive (simulator feed)
MarketIEX / ISO price feedsRESTplanned
IdentityMicrosoft Entra ID, Okta, KeycloakOIDC / SAML federation; built-in password IdP todaybuilt-in live · federation planned
Files & modelsCSV / Parquet import, CIM/CGMES, glTF site kits, OpenUSD export (R4)partial

Vendor and product names are the property of their respective owners and are listed to describe interoperability targets, not partnerships or endorsements.

Roadmap

What ships today and what is next.

Release status as of September 2026. 'Live' features run in our hosted environment and in the local installer; 'in progress' features exist behind flags or in partial form.

  1. R0live

    Foundation

    • Streaming event backbone and time-series store
    • CIM/CGMES-aligned twin model
    • IEEE 738 DLR engine
    • Cloud and on-premises installers
  2. R1live

    First value

    • DLR + forecast with evidence export
    • Fleet health & RUL
    • ROI ledger
    • 28-route operations console
    • Identity, RBAC, login
  3. R2in progress

    Expand

    • Hosting capacity + persisted queue
    • Developer portal
    • DC power flow & scenarios
    • Lansub AI: self-hosted agent, autopilot with guardrails, feedback learning
    • Enterprise ops: MES, warehouse, supply chain, maintenance
    • Protocol connectors (OPC UA, 61850, DNP3, Modbus, MQTT)
  4. R3in progress

    Harden

    • Health index across all classes
    • Compliance packs (FERC 881, NERC CIP, ISO 55000 evidence)
    • Hash-chained audit ✓
    • IEC 62443 zone model
  5. R4planned

    Scale

    • Guard-railed write-back adapters (EMS/EAM)
    • OpenUSD / Omniverse export
    • Multi-region SaaS
  6. R5planned

    Platform

    • Model marketplace
    • Multi-energy (H₂, heat, V2G)
    • Partner SDK

Deployment

Your cloud, our cloud, or your data centre.

Managed by Lansub

Dedicated tenant on Microsoft Azure in your preferred region (Central India by default). We run, patch and scale; SSO federates to your identity provider.

Your Azure subscription

Infrastructure-as-code templates deploy the full stack under your governance and cost centre, using containers or your managed services.

On-premises / air-gapped

The same platform packaged for your data centre, container-based, with offline update bundles for control-room networks.

See Digital Twin on your own network data.

A 45-minute working session with our grid engineers on a sanitised slice of your topology and telemetry, followed by a scoped 90-day pilot proposal.